Commit Graph

6 Commits

Author SHA1 Message Date
Yaowu Xu
3dbc78b134 Enable 32x32 dct tests
Also
1. Removed the test code for fDCT from the iDCT test.
2. changed the criteria of round trip error to be below 1/block, this
is quite strict comparing to smaller transforms when size differences
are accounted for.

Change-Id: Idb46a6380b04c93fc8e2845c75f5a850366b0090
2013-02-26 09:23:01 -08:00
Paul Wilkins
649be94cf0 Removal of Hybrid DWT/DCT experiment.
Removal of experiment to simplify code base for other
changes.

Change-Id: If0a33952504558511926ad212bc311fc2bffb19a
2013-02-13 15:08:48 +00:00
Ronald S. Bultje
55657aac49 Fix wrong pitch argument in dct32x32 unit test.
Change-Id: Id9474a1686daebfa3d004e21823bf1888ec9e534
2013-01-10 08:36:42 -08:00
Ronald S. Bultje
aa2effa954 Merge tx32x32 experiment.
Change-Id: I615651e4c7b09e576a341ad425cf80c393637833
2013-01-10 08:23:59 -08:00
Yaowu Xu
c681887652 fixed build issue with round()
not defined in msvc

Change-Id: I8fe8462a0c2f636d8b43c0243832ca67578f3665
2012-12-13 15:15:56 -08:00
Ronald S. Bultje
c456b35fdf 32x32 transform for superblocks.
This adds Debargha's DCT/DWT hybrid and a regular 32x32 DCT, and adds
code all over the place to wrap that in the bitstream/encoder/decoder/RD.

Some implementation notes (these probably need careful review):
- token range is extended by 1 bit, since the value range out of this
  transform is [-16384,16383].
- the coefficients coming out of the FDCT are manually scaled back by
  1 bit, or else they won't fit in int16_t (they are 17 bits). Because
  of this, the RD error scoring does not right-shift the MSE score by
  two (unlike for 4x4/8x8/16x16).
- to compensate for this loss in precision, the quantizer is halved
  also. This is currently a little hacky.
- FDCT and IDCT is double-only right now. Needs a fixed-point impl.
- There are no default probabilities for the 32x32 transform yet; I'm
  simply using the 16x16 luma ones. A future commit will add newly
  generated probabilities for all transforms.
- No ADST version. I don't think we'll add one for this level; if an
  ADST is desired, transform-size selection can scale back to 16x16
  or lower, and use an ADST at that level.

Additional notes specific to Debargha's DWT/DCT hybrid:
- coefficient scale is different for the top/left 16x16 (DCT-over-DWT)
  block than for the rest (DWT pixel differences) of the block. Therefore,
  RD error scoring isn't easily scalable between coefficient and pixel
  domain. Thus, unfortunately, we need to compute the RD distortion in
  the pixel domain until we figure out how to scale these appropriately.

Change-Id: I00386f20f35d7fabb19aba94c8162f8aee64ef2b
2012-12-07 14:45:05 -08:00