Creates a merge between the master and experimental branches. Fixes a
number of conflicts in the build system to allow *either* VP8 or VP9
to be built. Specifically either:
$ configure --disable-vp9 $ configure --disable-vp8
--disable-unit-tests
VP9 still exports its symbols and files as VP8, so that will be
resolved in the next commit.
Unit tests are broken in VP9, but this isn't a new issue. They are
fixed upstream on origin/experimental as of this writing, but rebasing
this merge proved difficult, so will tackle that in a second merge
commit.
Change-Id: I2b7d852c18efd58d1ebc621b8041fe0260442c21
In the variance calculations the difference is summed and later squared.
When the sum exceeds sqrt(2^31) the value is treated as a negative when
it is shifted which gives incorrect results.
To fix this we force the multiplication to be unsigned.
The alternative fix is to shift sum down by 4 before multiplying.
However that will reduce precision.
For 16x16 blocks the maximum sum is 65280 and sqrt(2^31) is 46340 (and
change).
This change is based on:
1698234 Missed some variance casts
fea3556 Fix variance overflow
Change-Id: I2c61856cca9db54b9b81de83b4505ea81a050a0f
s/([vV][pP])8/$19/
additionally dct.h was removed; declare the _c functions that are used
in the tests. the TODO for conversion to parameterized tests still
remains.
Change-Id: I73db9425a57075bbb78a92693ba6b320578981cd
there are still a couple type of warning left, which are related to
double constants assigned to float type. As those would be addressed
by the conversion of transforms into integer version. This commit
has left those un-dealt with.
Change-Id: I48fd9b489c0c27ad6b543f4177423419f929f2bb
The block sizes for decoding tokens are up to 16x16, which means
eobs is within [0, 256]. Using (signed) char is not enough. Changed
eobs data type to unsigned short to fix the problem.
Change-Id: I88a7d3098e1f1604c336d6adb88ffec971fb03a6