For non-static functions, change the prefix to vp9_. For static functions,
remove the prefix. Also fix some comments, remove unused code or unused
function prototypes.
Change-Id: I1f8be05362f66060fe421c3d4c9a906fdf835de5
Most of these were picked up in the previous commit (prefix change from
vp8_ to vp9_), but I'm pushing this separately so that it's easier to
review.
Change-Id: I91e959895778b8632d7d33375523df8a7568a490
Converted the forward and inverse transforms to integer forms.
Modify #define TEST_INT 1/0
in the code to call integer/float version of transforms.
The tests showed that average OVERALL PSNR loss was less than 0.1%.
Change-Id: I1dfa4eeab6412597e3b970ce299cf0e116a917e6
Separates the logic on transform type selection previously spread out
over a number of files into a separate function. Currently the tx_type
field in b_mode_info is not used, but still left in there to eventually
use for signaling the transform type in the bitstream.
Also, now for tx_type = DCT_DCT, the regular integer DCT is used, as
opposed to the floating point DCT used in conjuction with hybrid
transform.
Results change somewhat due to the transform change, but are within
reasonable limits. The hd/std-hd sets are slightly up, while derf/yt
are slightly down.
Change-Id: I5776840c2239ca2da31ca6cfd7fd1148dc5f9e0f
This commit fixes unsafe simd / floating point interactions arising
from the current hybrid and 16x16 transform implementation.
These led to a raft of bugs and issues when the project was
built using VS2008 for Win32 though they did not show up with
the unix builds.
Gerrit makes a meal out of presenting the fix but all I have actually
done is indent the body of each function that uses floating point by
one level and bracket with emms instructions using the function
vp8_clear_system_state(). See below.
function () {
vp8_clear_system_state();
{
... function body
}
vp8_clear_system_state();
}
This is almost certainly over the top in terms of number of emms
instructions but is a temporary measure pending implementation of
integer variants of each function to replace the floating point.
Limited testing suggests that this fixes the problems that arose for
Win32 VS2008 when the hybrid or 16x16 transforms were enabled.
Change-Id: I7c9a72bd79315246ed880578dec51e2b7c178442
Separates the entropy coding context models for 4x4, 8x8 and 16x16
ADST variants.
There is a small improvement for HD (hd/std-hd) by about 0.1-0.2%.
Results on derf/yt are about the same, probably because there is not
enough statistics.
Results may improve somewhat once the initial probability tables are
updated for the hybrid transforms which is coming soon.
Change-Id: Ic7c0c62dacc68ef551054fdb575be8b8507d32a8
Enable ADST/DCT of dimension 16x16 for I16X16 modes. This change provides
benefits mostly for hd sequences.
Set up the framework for selectable transform dimension.
Also allowing quantization parameter threshold to control the use
of hybrid transform (This is currently disabled by setting threshold
always above the quantization parameter. Adaptive thresholding can
be built upon this, which will further improve the coding performance.)
The coding performance gains (with respect to the codec that has all
other configuration settings turned on) are
derf: 0.013
yt: 0.086
hd: 0.198
std-hd: 0.501
Change-Id: Ibb4263a61fc74e0b3c345f54d73e8c73552bf926
The commit replaces run-time initialization of cosine constants with
static constant values, which provides ~30% relief on slow speed. The
real solution, however will be to implement integer versions of those
functions that current use float/double.
Change-Id: Ie3ff1793509653d78dd1aeaf88cc6737da1bc55f
The forward and inverse hybrid transforms are now performed using
single function modules, where the dimension is sent as argument.
Added an inline function clip8b to clip the reconstruction pixels
into range of 0-255.
Change-Id: Id7d870b3e1aefc092721c80c0af6f641eb5f3747
Fixed the code review comments.
Under the htrans8x8 experiment the 8X8 DCT in the
I8X8 mode is replaced with a combination of 8X8 ADST and
DCT.
Overall coding gains with the htrans8x8 experiment are:
derf: 0.486
std-hd: 1.040
hd: 1.063
yt: 0.506
Note that part of the gain comes from bigger transforms
(8x8 instead of 4x4) and part comes from replacing the DCT
wth the ADST.
Change-Id: I92ca6bbfce11b4165d612b81d9adfad4d010c775
Set on all 16x16 intra/inter modes
Features:
- Butterfly fDCT/iDCT
- Loop filter does not filter internal edges with 16x16
- Optimize coefficient function
- Update coefficient probability function
- RD
- Entropy stats
- 16x16 is a config option
Have not tested with experiments.
hd: 2.60%
std-hd: 2.43%
yt: 1.32%
derf: 0.60%
Change-Id: I96fb090517c30c5da84bad4fae602c3ec0c58b1c
Adds ADST/DCT hybrid transform coding for Intra4x4 mode.
The ADST is applied to directions in which the boundary
pixels are used for prediction, while DCT applied to
directions without corresponding boundary prediction.
Adds enum TX_TYPE in b_mode_infor to indicate the transform
type used.
Make coding style consistent with google style.
Fixed the commented issues.
Experimental results in terms of bit-rate reduction:
derf: 0.731%
yt: 0.982%
std-hd: 0.459%
hd: 0.725%
Will be looking at 8x8 transforms next.
Change-Id: I46dbd7b80dbb3e8856e9c34fbc58cb3764a12fcf
the integer version has very good precision, the float version is no
longer useful. this commit also removes the experiment option from
configure script.
Change-Id: Ibb92e63c9f5083357cdf89c559d584a7deb3353f
This commit adds lossless compression capability to the experimental
branch. The lossless experiment can be enabled using --enable-lossless
in configure. When the experiment is enabled, the encoder will use
lossless compression mode by command line option --lossless, and the
decoder automatically recognizes a losslessly encoded clip and decodes
accordingly.
To achieve the lossless coding, this commit has changed the following:
1. To encode at lossless mode, encoder forces the use of unit
quantizer, i.e, Q 0, where effective quantization is 1. Encoder also
disables the usage of 8x8 transform and allows only 4x4 transform;
2. At Q 0, the first order 4x4 DCT/IDCT have been switched over
to a pair of forward and inverse Walsh-Hadamard Transform
(http://goo.gl/EIsfy), with proper scaling applied to match the range
of the original 4x4 DCT/IDCT pair;
3. At Q 0, the second order remains to use the previous
walsh-hadamard transform pair. However, to maintain the reversibility
in second order transform at Q 0, scaling down is applied to first
order DC coefficients prior to forward transform, and scaling up is
applied to the second order output prior to quantization. Symmetric
upscaling and downscaling are added around inverse second order
transform;
4. At lossless mode, encoder also disables a number of minor
features to ensure no loss is introduced, these features includes:
a. Trellis quantization optimization
b. Loop filtering
c. Aggressive zero-binning, rounding and zero-bin boosting
d. Mode based zero-bin boosting
Lossless coding test was performed on all clips within the derf set,
to verify that the commit has achieved lossless compression for all
clips. The average compression ratio is around 2.57 to 1.
(http://goo.gl/dEShs)
Change-Id: Ia3aba7dd09df40dd590f93b9aba134defbc64e34
The commit added an integer version of 8x8 forward DCT, based on the
orginal forward DCT from VP6. The constants, roundings, and shifts
were adjusted to improve the accuracy. The latest patch has a very
similar accuracy in term of round trip error against the floating
point version.
It should be noted here that the purpose of the patch is to help
encoding speed and facilitate all other experiments. There will be
futher review in combination with inverse DCT before finalization.
configure with "--enable--int_8x8fdct" to use the integer version
Change-Id: I5a4f80507429f0e07cf02a13768ec81cbfddc5bc
This commit changed the forward and the inverse 4x4 Walsh Hadamard
transform to a new pair, where the inverse transform can pefectly
reconstuct the input to forward transform. It also does so without
changing the input and output value range. Even more, it does not
change the complexity of the transforms.
While it was not expected to improve the results of our current test,
it does improve std-hd set by 0.2% on all metrics. No change on derf.
Change-Id: Ie4f23ddd3a0f3c5fbe97fb58399f860031f99337
the changes are still temporary, the final transforms, especially
inverse ones should take in account both accuracy, complexity, and
sign-bias, which should be decided at a later time.
Change-Id: I116b0c70b25f5ee324ae5713d4564f5d0aa27151
During the work of extend_qrange, we have rolled a factor of 2 from
quantization/dequatnization into 2nd order walsh-hadamard transform.
This commit does the same for the 2nd order haar transform. so they
can share the same quantizaiton process as the 2nd order WHT.
Change-Id: I734af4a20ea8149a01b5b1971a065092977dfe33
This commit added scaling factors to 8x8 transform, quant, dequant and
inverse transform pipeline to make 8x8 transform to work when configed
with enable-extend_qrange. This commit also disabled the trellis-quant
when extend_qrange is configured.
Change-Id: Icfb3192e4746f70a4bb35ad18b7b47705b657e52
With this fix, the experimental branch now builds and encodes correctly
with the following two configure options respectively:
--enable-experimental --enable-t8x8
--enable-experimental
Change-Id: I3147c33c503fe713a85fd371e4f1a974805778bf
Prior to this change, VP8 min quantizer is 4, which caps the
highest quality around 51DB. This experimental change extends
the min quantizer to 1, removes the cap and allows the highest
quality to be around ~73DB, consistent with the fdct/idct round trip
error. To test this change, at configure time use options:
--enable-experimental --enable-extend_qrange
The following is a brief log of changes in each of the patch sets
patch set 1:
In this commit, the quantization/dequantization constants are kept
unchanged, instead scaling factor 4 is rolled into fdct/idct.
Fixed Q0 encoding tests on mobile:
Before: 9560.567kbps Overall PSNR:50.255DB VPXSSIM:98.288
Now: 18035.774kbps Overall PSNR:73.022DB VPXSSIM:99.991
patch set 2:
regenerated dc/ac quantizer lookup tables based on the scaling
factor rolled in the fdct/idct. Also slightly extended the range
towards the high quantizer end.
patch set 3:
slightly tweaked the quantizer tables and generated bits_per_mb
table based on Paul's suggestions.
patch set 4:
fix a typo in idct, re-calculated tables relating active max Q
to active min Q
patch set 5:
added rdmult lookup table based on Q
patch set 6:
fix rdmult scale: dct coefficient has scaled up by 4
patch set 7:
make transform coefficients to be within 16bits
patch set 8:
normalize 2nd order quantizers
patch set 9:
fix mis-spellings
patch set 10:
change the configure script and macros to allow experimental code
to be enabled at configure time with --enable-extend_qrange
patch set 11:
rebase for merge
Change-Id: Ib50641ddd44aba2a52ed890222c309faa31cc59c
Changes 'The VP8 project' to 'The WebM project', for consistency
with other webmproject.org repositories.
Fixes issue #97.
Change-Id: I37c13ed5fbdb9d334ceef71c6350e9febed9bbba
Besides the slight improvement in round trip error. This
also fixes a sign bias in the forward transform, so the
round trip errors are evenly distributed between +1s and
-1s. The old bias seemed to work well with the dc sign bias
in old fdct, which no longer exist in the improved fdct.
Change-Id: I8635e7be16c69e69a8669eca5438550d23089cef
The new fdct lowers the round trip sum squared error for a
4x4 block ~0.12. or ~0.008/pixel. For reference, the old
matrix multiply version has average round trip error 1.46
for a 4x4 block.
Thanks to "derf" for his suggestions and references.
Change-Id: I5559d1e81d333b319404ab16b336b739f87afc79
When the license headers were updated, they accidentally contained
trailing whitespace, so unfortunately we have to touch all the files
again.
Change-Id: I236c05fade06589e417179c0444cb39b09e4200d